84: W-phase output phase loss (oPL3)
87: Low frequency overload protection (oL3)
89: Rotor position detection error (roPd)
101: CANopen guarding error (CGdE)
102: CANopen heartbeat error (CHbE)
104: CANopen bus off error (CbFE)
105: CANopen index error (CidE)
106: CANopen slave station setting error (CAdE)
107: CANopen index setting exceed limit (CFrE)
111: InrCOM time-out error (ictE)
121: Internal communication error (CP20)
123: Internal communication error (CP22)
124: Internal communication error (CP30)
126: Internal communication error (CP32)
127: Internal communication error (CP33)
128: Over-torque 3 (ot3)
129: Over-torque 4 (ot4)
134: Electronics thermal relay 3 protection (EoL3)
135: Electronics thermal relay 4 protection (EoL4)
140: Oc hardware error (Hd6)
141: GFF occurs before run (b4GFF)
142: Auto-tuning error 1
(no feedback current error) (AUE1)
143: Auto-tuning error 2
(motor phase loss error) (AUE2)
144: Auto-tuning error 3
(no-load current I
0
measuring error) (AUE3)
Pr.
Explanation
Settings
Default
06-29
PTC detection selection
0: Warn and continue operation
1: Fault and ramp to stop
2: Fault and coast to stop
3: No warning
0
Pr.
Explanation
Settings
Default
06-30
PTC level
0.0 to 100.0%
50.0