Operating Instructions
Specifications
Environment for Operation, Storage and Transportation
18 | 443
Signal
4 to 20 mA / 0 to 10V
1 channel pulse input (33 kHz), 1 channel pulse output (33 kHz)
Main Functions
Multiple motor switching (a maximum of four independent motor parameter settings), Fast start-up,
Deceleration Energy Back (DEB) function, Wobble frequency function, Fast deceleration function,
Master and Auxiliary frequency source selectable, Restart after momentary power loss, Speed
tracking, Over-torque detection, 16-step speed (including the master speed), Accel. time switch, S-
curve accel., three-wire operation control, JOG frequency, Frequency upper/lower limit settings, DC
brake at start-up and stop, and PID control.
Application Macro
Built-in application parameter groups (selected by industry) and user-defined application parameter
groups.
Protection
Characteristics
Motor Protection
Over-current, Over-voltage, Over-heating, Phase loss.
Stall Prevention
Stall prevention during acceleration, deceleration and running (independent settings).
Accessory
Communication
Cards
DeviceNet, EtherNet/IP, PROFIBUS DP, Modbus TCP, CANopen, EtherCAT
Certifications
UL, CE, RCM, TÜV (SIL 2), RoHS, REACH
[Note 1]
Control accuracy may vary depending on the environment, application conditions or different motors.
Environment for Operation, Storage and Transportation
DO NOT expose the AC motor drive to a poor environment, such as one with dust, direct sunlight, corrosive/ inflammable gasses, humidity,
liquids, or excessive vibration. The salt in the air must be less than 0.01 mg/cm
2
every year.
Environment
Installation Location
IEC 60364-1/IEC 60664-1 Pollution degree 2, Indoor use only.
Surrounding
Temperature
Operation
IP20/UL Open Type
-4 to 122°F (-20 to 50°C)
-4 to 140°F (-20 to 60°C) with derating
Zero stack Installation
-4 to 104°F (-20 to 40°C)
-4 to 122°F (-20 to 50°C) with derating
Side-by-side installation
-4 to 122°F (-20 to 50°C)
-4 to 140°F (-20 to 60°C) with derating
Storage
-40 to 185°F (-40 to 85°C)
Transportation
-4 to 158°F (-20 to 70°C)
Non-condensing, non-freezing
Rated Humidity
Operation
Maximum 90%
Storage/Transport
Maximum 95%
No water condensation
Air Pressure
Operation
86 to 106 kPa
Storage/Transport
70 to 106 kPa
Pollution Level
IEC 60721-3
Operation
Class 3C2; Class 3S2
Storage
Class 2C2; Class 2S2
Transportation
Class 1C2; Class 1S2
Concentrate prohibited
Altitude
<1000 m (For altitudes > 1000 m, with derating.)