Operating Instructions

Specifications
Derating for Ambient Temperature, Altitude and Carrier Frequency
19 | 443
Package Drop
Storage/Transport
ISTA procedure 1A (according to weight) IEC 60068-2-31
Vibration
Operating
1.0 mm, peak to peak value range from 213.2 Hz;
0.72.0 G range from 13.255 Hz;
2.0 G range from 55512 Hz.
Compliance with IEC 60068-2-6
Non-operating
2.5 G peak, 5 Hz2 kHz
0.015" maximum displacement
Impact
Operating
15 G, 11 ms
Compliance with IEC/EN60068-2-27
Non-operating
30 G
Protection Level
Operating Environment
IP20/
UL Open Type
If the AC motor drive operates at the rated current, the ambient temperature needs to be
between -4 and 122°F (-20and 50°C). If the temperature is above 122°F (50°C), decrease
2.5% of the rated current for every 1°C increase in temperature. The maximum allowable
temperature is 140°F (60°C.)
High Altitude
If the AC motor drive is installed at an altitude up to 3,280 ft (1000 m), follow normal
operation restrictions. For altitudes of 3,280 to 6,561 ft (1000 to 2000 m), decrease the
drive’s rated current by 1% or lower the temperature by 0.5°C for every 328 ft (100 m)
increase in altitude. The maximum altitude for corner grounded is 6,561 ft (2000 m).