Operating Instructions

Descriptions of Parameter Settings
Descriptions of Parameter Settings
231 | 443
Pr.
Explanation
Settings
Default
10-16
Pulse input type setting
0: Disabled
5: Single-phase input (MI7)
0
Pr.
Explanation
Settings
Default
10-17
Electrical gear A
1 to 65535
100
10-18
Electrical gear B
1 to 65535
100
Pr.
Explanation
Settings
Default
10-21
PG2 pulse input speed command
low pass filter time
0.000 to 65.535 sec.
0.100
Pr.
Explanation
Settings
Default
10-24
FOC & TQC function control
0 to 65535
0
bit
Description
0
ASR controller under torque control.
0: use PI as ASR; 1: use P as ASR
110
N/A
11
Activates the DC brake when executing the zero torque command.
0:ON; 1:OFF
12
FOC sensorless mode with crossing zero means the speed goes from negative to positive or positive to negative (forward to
reverse direction or reverse to forward direction).
0: determined by the stator frequency; 1: determined by the speed command
13
N/A
14
N/A
15
Direction control in open-loop torque
0: Switch ON direction control; 1: Switch OFF direction control