Operating Instructions
Descriptions of Parameter Settings
Descriptions of Parameter Settings
243 | 443
when the motor drives the load and the torque command is in the same direction as the speed limit, you can set the
speed limit according to Pr.00-20.
In torque control mode, the F page of keypad displays the present speed limit value. For details on the keypad
display, refer to the LED Function Description in Section 7-14 Digital Keypad (optional).
Fig. 117:
Pr.
Explanation
Settings
Default
11-37
Forward speed limit
(Torque mode)
0 to 120%
10
11-38
Reverse speed limit
(Torque mode)
0 to 120%
10
Limits the speed for forward and reverse running in torque mode (Pr.01-00 Maximum Operation Frequency =
100%).
Pr.
Explanation
Settings
Default
11-41
PWM mode selection
0: Two-phase modulation mode
2: Space vector modulation mode
2