Operating Instructions
Digital Keypad
Keypad Operation Process
28 | 443
Fig. 19:
Use Pr.13-01–Pr.13-50 to set the user-defined parameters in sequence according to your requirement. The default
setting 0.00 means there is no user-defined parameter. Press ENTER to set the corresponding parameters for
Pr.13-01– Pr.13-50.
The setting method of user-defined parameters is the same as that for non-user-defined parameters. You can use
the Up and Down keys or left shift key to speed up the settings.
Example:
Setting Pr.13-01 to the user-defined parameter 04-00. First, press ENTER at Pr.13-01 to enter the setting page.
Then, long press MODE to enable the left shift key to start the setting. The setting process shows as follows.
You must set Pr.13-01, 02……50 in sequence, or the display shows Err.
After finishing the setting, press MODE to return to the APP page, and then press ENTER. The keypad displays
USEr. After you press ENTER again, the corresponding parameter that you set appears.
Example:
If you set Pr.13-01 as the user-defined parameter Pr.04-00, and Pr.13-02 as Pr.04-01, the parameters you set
appear when you press ENTER at the USEr page.