Operating Instructions
Digital Keypad
Keypad Operation Process
29 | 443
To remove a set user-defined parameter, remove from the last defined parameter (set to 0.00) first, or the display
shows Err. For example, if there are five user-defined parameters (Pr.13-01, 13-02…13-05), to remove Pr.13-02,
you must remove Pr.13-05 first, then 13-04, then 13-03, and then 13-02.
Parameter setting
D-1. Unsigned parameter
(Parameter setting range ≥ 0; for example, Pr.01-00)
Without using the left shift key: Use the Up and Left/Down key to select and adjust the parameters. Then, press
ENTER to start the parameter settings.
Using the left shift key: Long press MODE for two seconds until the last digit of the parameter value starts to blink.
Increase the value by pressing the Up key. The value goes back to 0 after 9.
Press the Left/Down key to shift the blinking cursor one digit to the left, and increase the value by pressing the Up
key.
After you finish setting the parameter, manually disable the left shift key function by pressing MODE for two
seconds.
Example:
The default setting for Pr.01-00 is 60.00. Long pressing MODE for two seconds enables the left shift function. The
process for pressing the Left/Down key shows as follows:
The upper limit for Pr.01-00 is 599.00. If you set a value greater than 599.00, Err appears after you press ENTER,
and then the keypad shows the upper limit (599.00) for a second to remind you of the incorrect setting. The setting
value remains as the original set value and the cursor returns to the last digit.
D-2. Minus-signed parameter setting status 1
(Parameter setting range can be < 0; for example, Pr.03-03)
Without using the left shift key: Use the Up and Left/Down keys to select and adjust the parameters. Then, press
ENTER to start the parameter settings.
Using the left shift key: Long press MODE for two seconds until the last digit of the parameter value starts to blink.
Increase the value by pressing the Up key. The value goes back to 0 after 9.
Press the Left/Down key to shift the blinking cursor one digit to the left, and increase the value by pressing the Up
key. When you shift to the first digit and press the Up key, the digit 0 changes to “-” (minus).
After you finish setting the parameter, manually disable the left shift key function by pressing MODE for two
seconds.
Example:
The default setting for Pr.03-03 is 0.0. Long pressing MODE for two seconds enables the left shift function. The
process for pressing the Left/Down key shows as follows:
The upper limit for Pr.03-03 is 100.0 and lower limit is -100.0. If you set a value greater than 100.0 or less than -
100.0, Err appears after you press ENTER, and then the keypad shows the upper limit (100.0) or lower limit (-
100.0) for a second to remind you of the incorrect setting. The setting value remains as the original set value, and
the cursor returns to the last digit.
D-3. Minus-signed parameter setting status 2
(Parameter setting range can be < 0, and the lower limit is ≤ -100.00 with two decimal places; for example, Pr.03-
74)