Operating Instructions
Warning Codes
Digital Keypad RT-KEYPAD
292 | 443
Warning setting parameter
N/A
Reset method
Cycle the power
Reset condition
N/A
Record
N/A
Cause
Corrective Actions
The drive detects that DeviceNet has no
power
Check if the cable and power is normal. If yes, return to the factory for repair.
ID No.
Display on LCD Keypad
Warning Name
Description
75
ExCom factory defect
(ECFF)
Factory default setting error
Action and Reset
Action level
Factory default setting error
Action time
Immediately act
Warning setting parameter
N/A
Reset method
Cycle the power
Reset condition
N/A
Record
N/A
Cause
Corrective Actions
Factory default setting error
Use DCISoft to reset to the default value.
ID No.
Display on LCD Keypad
Warning Name
Description
76
ExCom inner error (ECiF)
Serious internal error
Action and Reset
Action level
Internal memory saving error
Action time
Immediately act
Warning setting parameter
N/A
Reset method
Cycle the power
Reset condition
N/A
Record
N/A
Cause
Corrective Actions
Noise interference
Verify the wiring of the control circuit, and the wiring/grounding of the main circuit to prevent
interference.
Cycle the power.
The memory is broken
See the default value and check if the error still exists. If yes, replace the communication card.