Operating Instructions
Summary of Parameter Settings
00 Drive Parameters
34 | 443
Pr.
Explanation
Settings
Default
43: PID compensation (o.) (unit: %)
44: PID output frequency (b.) (unit: Hz)
46: Auxiliary frequency value (U.) (unit: Hz)
47: Master frequency value (A) (unit: Hz)
48: Frequency value after addition and subtraction of master and
auxiliary frequency (L.) (unit: Hz)
51: PMSVC torque offset
58: Pr.00-05 User gain display (K) (Does not display decimal places.)
62: I2t (o.) (unit: %)
63: Error code (E.)
64: Warning code (n.)
65: Accumulated motor operation record (day) (r.) (refer to Pr.05-32)
00-05
Coefficient gain in actual output
frequency
0.00–160.00
1.00
00-06
Firmware version
Read only
Read only
00-07
Parameter protection password
input
0–65535
Display: 0–4 ( the number of password attempts allowed)
0
00-08
Parameter protection password
setting
0–65535
0: No password protection or password entered correctly (Pr.00-07)
1: Parameter has been set
0
00-10
Control mode
0: Speed Control mode
2: Torque mode
0
00-11
Speed Control mode
0: IMVF (IM V/F control)
1: IMVFPG (IM V/F control + encoder)
2: IM/PM SVC (IM / PM space vector control)
5: IMFOC Sensorless (IM field-oriented sensorless vector control)
0
00-16
Load selection
0: Normal load
1: Heavy load
1
00-17
Carrier frequency
Note: When Pr.00-11=5 (IMFOC
Sensorless), the maximum setting
value for Pr.00-17 Carrier
frequency is 10 kHz.
Normal load: 2–15 kHz
Heavy load: 2–15 kHz
4
4
00-19
PLC command mask
bit 0: Control command is forced by PLC control
bit 1: Frequency command is forced by PLC control
bit 3: Torque command is forced by PLC control
Read only
00-20
Master frequency command
source (AUTO, REMOTE)
Note: HOA (Hand-Off-Auto)
function is valid only when you
use with MO function setting 42
and 56 or with KPC-CC01
(optional).
0: Digital keypad
1: RS-485 communication input
2: External analog input (Refer to Pr.03-00)
3: External UP/DOWN terminal (multi-function input terminals)
4: Pulse input without direction command (See Pr.10-16 without
considering direction)
6: CANopen communication card
7: Digital keypad potentiometer knob
8: Communication card (does not include CANopen card)
9: PID controller
0