Operating Instructions

Summary of Parameter Settings
00 Drive Parameters
35 | 443
Pr.
Explanation
Settings
Default
00-21
Operation command source
(AUTO, REMOTE)
Note: HOA (Hand-Off-Auto)
function is valid only when you
use with MO function setting 42
and 56 or with KPC-CC01
(optional).
0: Digital keypad
1: External terminals
2: RS-485 communication input
3: CANopen communication card
5: Communication card (does not include CANopen card)
0
00-22
Stop method
0: Ramp to stop
1: Coast to stop
0
00-23
Motor direction control
0: Enable forward/reverse
1: Disable reverse
2: Disable forward
0
00-24
Digital operator (keypad)
frequency command memory
Read only
Read only
00-25
User-defined characteristics
bit 03: user-defined decimal places
0000h-0000b: no decimal place
0001h-0001b: one decimal place
0002h-0010b: two decimal places
0003h-0011b: three decimal places
bit 45: user-defined unit
000xh: Hz
001xh: rpm
002xh: %
003xh: kg
004xh: m/s
005xh: kW
006xh: HP
007xh: ppm
008xh: 1/m
009xh: kg/s
00Axh: kg/m
00Bxh: kg/h
00Cxh: lb/s
00Dxh: lb/m
00Exh: lb/h
00Fxh: ft/s
010xh: ft/m
011xh: m
012xh: ft
013xh: degC
014xh: degF
015xh: mbar
016xh: bar
017xh: Pa
018xh: kPa
019xh: mWG
01Axh: inWG
01Bxh: ftWG
0