Operating Instructions

Option Cards
RT-PROFIB-COM
442 | 443
Wire gauge: 0.250.5 mm
2
[2420 AWG]
Stripping length: 78 mm
Screw torque: 2 kg-cm / [1.7 Ib-in.] / [0.2 Nm]
1. Screw fixing hole
2. Positioning hole
3. AC motor drive
connection port
4. Communication port
5. Indicator
NET1, NET2
6. Ground terminal block
Socket
PIN
Signal
Definition
1
CAN_H
CAN_H bus line (dominant high)
2
CAN_L
CAN_L bus line (dominant low)
3
CAN_GND
Ground/0V/V-
7
CAN_GND
Ground/0V/V-
Interface
RJ45
Number of ports
2 Port
Transmission method
CAN
Transmission cable
CAN standard cable
Transmission speed
1 Mbps; 500 kbps; 250 kbps; 125 kbps; 100 kbps; 50 kbps
Communication protocol
CANopen protocol
Terminating resistance
RT-PROFIB-COMM contains terminal resistance accessories. Install the terminal resistance
accessories to one of the network connectors when using RT-PROFIB-COMM.