Operating Instructions
Summary of Parameter Settings
03 Analog Input/Output Parameters
45 | 443
Pr.
Explanation
Settings
Default
02-80
Automatic positioning
deceleration time
0.00: Disable the function
0.01–100.00 sec.
0.00
02-81
EF activates when the terminal
count value reached
0: Terminal count value reached, no EF displays (continues to operate)
1: Terminal count value reached, EF activates
0
02-82
Initial Frequency command (F)
mode after stop
0: Use current Frequency command
1: Use zero Frequency Command
2: Refer to Pr.02-83 to set up
0
02-83
Initial Frequency command (F)
setting after stop
0.00–599.00 Hz
60.00
03 Analog Input/Output Parameters
indicates the parameter can be set during operation.
Pr.
Explanation
Settings
Default
03-00
Analog input selection (AVI)
0: No function
1: Frequency command
2: Torque command (torque limit under speed mode)
3: Torque compensation command
4: PID target value
5: PID feedback signal
6: Thermistor (PTC) input value
7: Positive torque limit
8: Negative torque limit
9: Regenerative torque limit
10: Positive / negative torque limit
11: PT100 thermistor input value
12: Auxiliary frequency input
13: PID compensation value
1
03-01
Analog input selection (ACI)
0
03-03
Analog input bias (AVI)
-100.0–100.0%
0
03-04
Analog input bias (ACI)
-100.0–100.0%
0
03-07
Positive/negative bias mode (AVI)
0: No bias
1: Lower than or equal to bias
2: Greater than or equal to bias
3: The absolute value of the bias voltage while serving as the center
4: Bias serves as the center
0
03-08
Positive/negative bias mode (ACI)
03-10
Reverse setting when analog
signal input is negative frequency
0: Negative frequency input is not allowed.
The digital keypad or external terminal controls the forward and reverse
direction.
1: Negative frequency input is allowed.
Positive frequency = run in a forward direction; negative frequency = run
in a reverse direction.
The digital keypad or external terminal control cannot change the
running direction.
0