Operating Instructions
Summary of Parameter Settings
07 Special Parameters
59 | 443
Pr.
Explanation
Settings
Default
07-22
Energy-saving gain
10 to 1000%
100
07-23
Automatic voltage regulation
(AVR) function
0: Enable AVR
1: Disable AVR
2: Disable AVR during deceleration
0
07-24
Torque command filter time
(V/F and SVC control mode)
0.001 to 10.000 sec.
0.050
07-25
Slip compensation filter time
(V/F and SVC control mode)
0.001 to 10.000 sec.
0.100
07-26
Torque compensation gain (V/F
and SVC control mode)
IM: 0 to 10 (when Pr.05-33 = 0)
PM: 0 to 5000 (when Pr.05-33 = 1 or 2)
1
07-27
Slip compensation gain
(V/F and SVC control mode)
0.00 to 10.00
0.00
(Default value
is 1.00 in SVC
mode)
07-29
Slip deviation level
0.0 to 100.0%
0: No detection
0
07-30
Over-slip deviation detection time
0.0 to 10.0 sec.
1.0
07-31
Over-slip deviation treatment
0: Warn and continue operation
1: Fault and ramp to stop
2: Fault and coast to stop
3: No warning
0
07-32
Motor oscillation compensation
factor
0 to 10000
1000
07-33
Auto-restart interval of fault
0.0 to 6000.0 sec.
60.0
07-38
PMSVC voltage feed forward gain
0.50 to 2.00
1.00
07-46
OOB sampling time
0.1 to 120.0 sec.
1.0
07-47
Number of OOB sampling times
00 to 32
20
07-48
OOB average sampling angle
Read only
Read only
07-62
dEb gain (Kp)
0 to 65535
8000
07-63
dEb gain (Ki)
0 to 65535
150
07-71
Torque compensation gain (motor
2)
IM: 0 to 10 (when Pr.05-33 = 0)
PM: 0 to 5000 (when Pr.05-33 = 1 or 2)
1
07-72
Slip compensation gain
(motor 2)
0.00 to 10.00
0.00
(Default value
is 1.00 in SVC
mode)