Parameter Description
User
Setting
r0000
Drive display (defined
in P0005)
r0002
Drive state (actual)
P0003
User access level
P0004
Parameter filter
P0005
Display selection for
r0000
P0006
Display mode for r0000
P0010
Commissioning
parameter filter
P0011
Lock for user-defined
parameter
P0012
Key for user-defined
parameter
P0013
User-defined
parameter
r0018
Firmware version
r0019
CO/BO: BOP control
word
r0020
CO: Actual frequency
setpoint
r0021
CO: Actual frequency
r0022
Actual Rotor speed
r0024
CO: Actual output
frequency
r0025
CO: Actual output
voltage
r0026
CO: Actual DC link
output voltage
r0027
CO: Actual output
current
r0031
Actual torque
r0032
Actual power
r0035
CO: Actual Motor
temperature
r0039
CO: Energy
consumption meter
P0040
Reset energy
consumption meter
r0050
CO: Active command
data set
r0052
CO/BO: Actual status
word 1
r0053
CO/BO: Actual status
word 2
r0054
CO/BO: Actual control
word 1
r0055
CO/BO: Additional
actual control word
r0056
CO/BO: Status of
motor control
r0061
Actual rotor speed
r0086
CO: Actual active
current
P0100
Europe/North America
power settings [kW or
hp]
Parameter Description
User
Setting
r0200
Actual power stack
code number
r0206
Rated inverter power
[kW]/[hp]
r0207
Rated inverter current
r0208
Rated inverter voltage
r0209
Maximum inverter
current
P0304
Rated motor voltage
P0304
Rated motor voltage
P0305
Rated motor current
P0307
Rated motor power
P0308
Rated motor cosPhi
P0309
Rated motor efficiency
P0310
Rated motor frequency
P0311
Rated motor speed
r0313
Motor pole pairs
P0340
Calculation of motor
parameters
P0350
Stator resistance (line-
to-line)
r0395
CO: Total stator
resistance [%]
P0400
Select encoder type
P0409
Pulses per second at
Rated Frequency
P0501
Type of sensor
P0506
Parameter list
P0507
Scalar values
P0508
Unit
P0509
String
P0601
Motor temp. sensor
P0610
Motor I
2
t temperature
reaction
P0640
Motor overload factor
[%]
P0700
Selection of command
source
P0701
Function of digital input
1
P0702
Function of digital input
2
P0703
Function of digital input
3
P0704
Function of digital input
4
P0705
Function of digital input
5
P0706
Function of digital input
6
P0707
Function of digital input
7
P0708
Function of digital input
8
P0718
CO/BO: Hand/Auto
r0722
CO/BO: Binary input
values
P0725
PNP/NPN digital inputs
P0731
BI: Function of digital
output 1
P0732
BI: Function of digital
output 2
r0747
CO/BO: State of digital
outputs
P0748
Invert digital outputs
Parameter Description
User
Setting
r0752
Actual input of ADC
(analog input) [V] or
[mA]
P0753
Smooth time ADC
(analog input)
r0754
Actual ADC (analog
input) value after
scaling [%]
r0755
CO: Actual ADC
(analog input) after
scaling [4000h]
P0756
Type of ADC (analog
input)
P0757
Value x1 of ADC
(analog input) scaling
[V/mA]
P0758
Value y1 of ADC
(analog input) scaling
P0759
Value x2 of ADC
(analog input) scaling
[V/mA]
P0760
Value y2 of ADC
(analog input) scaling
P0761
Width of ADC (analog
input) deadband
[V/mA]
P0771
CI: DAC (analog
output)
P0773
Smooth time DAC
(analog output)
r0774
Actual DAC (analog
output) value [V] or
[mA]
P0776
Type of DAC (analog
output)
P0777
Value x1 of DAC
(analog output) scaling
P0778
Value y1 of DAC
(analog output) scaling
P0779
Value x2 of DAC
(analog output) scaling
P0780
Value y2 of DAC
(analog output) scaling
P0781
Width of DAC (analog
output) deadband
P0809
Copy CDS (command
data set)
P0810
BI: CDS (command
data set) bit 0
(Local/Remote)
P0918
CB (communications
board or module)
address
P0927
Parameter changeable
via
r0947
Last fault code
r0948
Fault time
r0949
Fault value
P0952
Total number of faults
r0967
Control word 1
r0968
Statue word 1
P0970
Factory reset
P0971
Transfer data from
RAM to EEPROM