9. Reinstall control board grounding screw using a
Torx T20 driver (Figure 11). The grounding
screw also aids positioning and prevents rotation
of the control board.
Figure 11. Reinstalling Control Board
Grounding Screw.
10. Reinstall control module cover (Figure 12).
Figure 12. Reinstalling Control Module Cover.
11. Set Motor Frequency and Unit of Measurement
DIP switches (Figure 13) as follows:
DIP
Switch
Position Function
1 OFF
Not for customer use.
NOTE: This switch must
remain OFF for proper
operation.
2 ON
North American operation
(60 Hz, hp).
Figure 13. Setting Control Board DIP Switches.
12. Reinstall operator panel release button by using
a needle nose pliers to reinsert wire spring in
retaining slots (Figure 14).
Verify that release button and wire spring are
correctly mounted and securely in place.
Figure 14. Reinstalling Operator Panel