Index: r0947[0] : Recent fault trip --, fault
1
r0947[1] : Recent fault trip --, fault
2
r0947[2] : Recent fault trip -1, fault
3
r0947[3] : Recent fault trip -1, fault
4
r0947[4] : Recent fault trip -2, fault
5
r0947[5] : Recent fault trip -2, fault
6
r0947[6] : Recent fault trip -3, fault
7
r0947[7] : Recent fault trip -3, fault
8
Dependency: Index 2 used only if second fault occurs before first fault is acknowledged.
r0948[12] Fault time
Min: - Def: - Max: -
Level 3
Data: Time stamp to indicate when the fault has occurred. P2114 (run-time counter) or P2115 (real time clock) are the
possible sources of the time stamp.
Example: The time is taken from P2115 if this parameter has been updated with the real time. If not, P2114 is used
Index: r0948[0] : Recent fault trip --, fault time
seconds+minutes
r0948[1] : Recent fault trip --, fault time hours+days
r0948[2] : Recent fault trip --, fault time month+year
r0948[3] : Recent fault trip -1, fault time
seconds+minutes
r0948[4] : Recent fault trip -1, fault time hours+days
r0948[5] : Recent fault trip -1, fault time month+year
r0948[6] : Recent fault trip -2, fault time
seconds+minutes
r0948[7] : Recent fault trip -2, fault time hours+days
r0948[8] : Recent fault trip -2, fault time month+year
r0948[9] : Recent fault trip -3, fault time
seconds+minutes
r0948[10] : Recent fault trip -3, fault time hours+days
r0948[11] : Recent fault trip -3, fault time month+year`
Note: P2115 can be updated via AOP, Starter, DriveMonitor, etc.
r0949[8] Fault value
Min: - Def: - Max: -
Level 3
Index: r0949[0] : Recent fault trip --, fault value 1
r0949[1] : Recent fault trip --, fault value 2
r0949[2] : Recent fault trip -1, fault value 3
r0949[3] : Recent fault trip -1, fault value 4
r0949[4] : Recent fault trip -2, fault value 5
r0949[5] : Recent fault trip -2, fault value 6
r0949[6] : Recent fault trip -3, fault value 7
r0949[7] : Recent fault trip -3, fault value 8
P0952 Total number of faults
Min: 0 Def: 0 Max: 0
Level 3
Dependency: Setting 0 resets fault history (changing to 0 also resets parameter P0948-fault time).