Operating instructions

Parameter Table
10-100
© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC400
Inputs/Input 2
0.21.02
Status signal Min:
Max:
Default:
no signal
telegram (faulty)
no signal
0.21.01
Monitoring monitor input Min:
Max:
Default:
off
alarm
off
timeout Min:
Max:
Default:
5 min
1440 min
30 min
0.21.03
Framing baud rate Min:
Max:
Default:
0 Bd
4294967295 Bd
0 Bd
data bits Min:
Max:
Default:
0
8
0
parity Min:
Max:
Default:
none
odd
none
stop bits Min:
Max:
Default:
0
2
0
Outputs
0.12.01
Output 1 signal to output Min:
Max:
Default:
off
serial telegram
off
inverted Min:
Max:
Default:
no
yes
no
pretrigger Min:
Max:
Default:
0 ns
1000000 ns
0 ns
conditional output Min:
Max:
Default:
send unconditional
only if synchronized
send unconditional
Table 10-1 List of the parameters of SICLOCK TC400
Access
1)
/ No.
Parameter Entry Value Range / Default