Operating instructions

Configuration Tool
7-54
© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC400
7.2.2 Authorization
There are authorization levels for each parameter, which permit or prohibit read
and write access to the parameter. The user interface starts with the lowest autho-
rization level, which usually only permits read access to parameters.
More rights can be obtained by entering the appropriate password.
The password can be changed by the user:
/System/Authorization For Standard Protection (2.06.02)
parameter
As delivered, the password on the device is "2222"
The current authorization level is indicated by the color of the password field.
Write protection - red entry field
At this authorization level, the user
typically only has read access to standard
parameters.
Standard protection - green entry field
At this authorization level, the user typically also has read access to advanced
parameter
s and write access to standard parameters.
Online mode
Authorization is performed directly on the device
, i.e. the device assigns an
appropriate authorization level.
Offline mode
You can authorize yourself for a higher authorization level with a password, when
this is co
ntained in the loaded offline authorization parameters.
Note
The combination "0000" is not permitted as a password. Setting the password to
"0000" disables access with this authorization level. Access is then only possible
using the service password. The service password can be requested from Tech-
nical Assistance by an authorized person.
Note
It is not possible to authorize yourself in offline mode with a password that is avail-
able on the device, but is not contained in the offline authorization parameters.