9.2.3 OUTPUT 1 to 3 via terminals
Three parameterizable outputs are available on the terminals:
/Outputs/Output 1 (0.12.01)
parameter as current or voltage signal
/Outputs/Output 2 (0.13.01)
parameter as current or voltage signal
/Outputs/Output 3 (0.14.01)
parameter as RS422 signal
Output signal
The following output signals can be set via the param
eter entry "Signal to output":
DCF77 with local time
DCF77 with UTC
Pulse per second
Pulse per minute
Serial telegram
See Output telegram (for OUTPUT 1 to 3) (Section 9.2.5).
Inverted
You can invert the signal with the parameter entry "Inverted".
Pretrigger
The parameter entry "Pretrigger" is used to set how many nanoseconds before
th
e second
change the output should switch. With that, line delays can be com-
pensated.
Conditional output
The parameter entry "Conditional output" specifies whethe
r the signal should
always be output or only if synchronized. The required setting for the redundant
configuration of the outputs is described in OUTPUT 1 and 2 redundant
(Section 9.2.4).
Further information
Terminal assignment (Sec
tion 15.1)