Table 4.1: Connection of control inputs FP1 to FP4 with activation of field pairs
1 to 4.
The following rules apply for switching over eight field pairs:
The switchover must be made within 40 ms, i.e. after 40 ms an input
connection must be valid and stable. The old field pair is monitored during
the switchover time. The new field pair is monitored after max. 80 ms.
The switchover process performed by the control system must agree with
the Safety Sensor's configuration. This configuration is specified with the
configuration and diagnostics software.
Table 4.2: Connection of control inputs FP1 to FP4 with activation of field pairs
1 to 8.
Field pair
Control input
Description
FP1 FP2 FP3 FP4
1 1 0 0 0 Field pair 1 is active
2 0 1 0 0 Field pair 2 is active
3 0 0 1 0 Field pair 3 is active
4 0 0 0 1 Field pair 4 is active
Field pair Control input Description
FP1 FP2 FP3 FP4
1 1 0 0 0 Field pair 1 is active
2 0 1 0 0 Field pair 2 is active
3 0 0 1 0 Field pair 3 is active
4 0 0 0 1 Field pair 4 is active
5 1 1 1 0 Field pair 5 is active
6 1 1 0 1 Field pair 6 is active
7 1 0 1 1 Field pair 7 is active
8 0 1 1 1 Field pair 8 is active