Operating instructions
Passive Components for Electrical Networks
4-7
SIMATIC NET Tw isted-Pair and Fiber-Optic Networks
C79000-G8976-C125-02
Table 4-4 Mechanical Data of the ITP Standard Cable
Standard code
J-02YSCY 2x2x0,64/1,5 PIMF F GN
∅ Conductor
0.64 mm
∅ Outer (approx.)
(9.2x6 ± 0.5) mm
Approximate thickness of the outer sheath 0.8 mm
Bend radius:
Multiple bends
Single bend
Over the flat side
≥ 45 mm
≥ 30 mm
Tensile strength
≤80 N
Pressure load Maximum permitted load: 5 kN/10 cm
Test complying with IEC 794-1 E3
Temperature range:
Operation
Installation/assembly
Transport/storage
-40 °C...70 °C
-5°C...50 °C
-40 °C...70 °C
Copper weight 46 kg/km
Net weight 90 kg/km
Free of halogens no
Resistance to fire Flame-retardant complying with DIN VDE 0472,
Part 804 test type B and IEC 60332-1
Resistance to oil Resistant to mineral oils and fats complying with
VDE 0472 Part 803