Getting Started Edition 09/2005 Industrial PC Rack PC IL 43 simatic DOCUMENTATION
Introduction 1 Description 2 SIMATIC Application Planning 3 Industrial PC Rack PC IL 43 Mounting 4 Connecting 5 Commissioning 6 Dimension drawings 7 Appendix A Getting Started Edition 09/2005 A5E00432882-01
Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. Danger indicates that death or severe personal injury will result if proper precautions are not taken.
Table of contents 1 Introduction............................................................................................................................................. 1-1 2 Description.............................................................................................................................................. 2-1 3 4 5 6 7 A 2.1 External structure....................................................................................................................... 2-1 2.
Table of contents iv SIMATIC Rack PC IL 43 Getting Started, Edition 09/2005, A5E00432882-01
Introduction 1 Purpose of this document This Getting Started documentation contains all the information you need for commissioning and using the SIMATIC Rack PC IL 43. Scope of validity of this document This documentation is valid for all supplied variations of the SIMATIC Rack PC IL 43 and describes the state of delivery as of September 2005. Operating instructions SIMATIC Rack PC IL 43 Additional information is available on the supplied CD "Rack PC IL 43 Documentation and Drivers".
Introduction 1-2 SIMATIC Rack PC IL 43 Getting Started, Edition 09/2005, A5E00432882-01
2 Description 2.
Description 2.2 Operator controls 2.2 Operator controls Operator control on/off button Pos Description (1) The on/off/reset buttons have three functions: - Switch on the PC (press briefly 1x) - Shut down the operating system and PC (press briefly 1x) - Switch off the PC without shutting down the operating system (press and hold more than 4 seconds) = hardware reset Caution Data may be lost when the PC performs a hardware reset.
Description 2.3 Connecting elements 2.3 Connecting elements Interfaces Layout of the interfaces on the rear of the device Pos Name Description (1) MOUSE Connection for a PS/2 mouse (2) USB C and D USB connector (3) LPT Parallel interface, 25-pin (4) LAN RJ 45 Ethernet connection 10/100/1000 Mbps (5) COM 2 Serial port 1 (V.
Description 2.4 Status displays Power supply Position of the IEC power plug Description IEC power connector for the AC power supply to the device. The maximum permitted power range is 120 V AC to 240 V AC 2.
Application Planning 3.1 3 Transport Although the Rack PC has a rugged design, its internal components are sensitive to severe vibrations or shock. You must therefore protect the PC from severe mechanical stress when transporting it. You should always use the original packaging for shipment of the device. Caution Risk of damage to the device! When transporting the PC in cold weather it may be submitted to extreme variations in temperature.
Application Planning 3.2 Unpacking and checking the delivery unit Noting the device identification data The device can identified uniquely with the help of these numbers in case of repairs or theft. Enter the following data in the table below: • Serial number: The serial number (S VP) is located on the type plate either on the rear panel of the device or on the inside of the front door.
Application Planning 3.3 Ambient and environmental conditions 3.3 Ambient and environmental conditions When you plan your project, you should make allowances for: • Note the climatic and mechanical environmental conditions specified in the technical data in your operating manual. • Avoid extreme ambient conditions as much as possible. Protect your PC from dust, moisture, and heat.
Application Planning 3.
4 Mounting 4.1 Installing the device Possible areas of installation The device may be installed in control desks, switching cabinets and 19`` rack systems, both horizontally and vertically. Possible mounting methods Options of mounting the device • Mounting on angle brackets • Installation on device bases • Tower installation: a separate tower kit can be ordered for tower installation.
Mounting 4.2 Technical data of the telescopic rails Note For vertical operation, install the device on a horizontal metal base and secure it against tipping. The following decide bases are available from Rittal for this purpose: Rittal Type TE 7000.620, Rittal Type VR 3861.580, Rittal Type DK 7063.710. Please refer to the case manufacturer's instructions regarding device bases. Caution Danger of bodily harm! It is not permitted to install the device only on the 19" brackets of the front panel. 4.
Connecting 5.1 5 Connecting peripherals Note before connecting Notice Connect only I/O modules approved for industrial applications to EN 61000-6-2:2001. Note Hot-plug I/O modules (USB) may be connected while the PC is in operation. Caution I/O devices not capable of hot-plugging may only be connected after the device has been disconnected from the power supply. Caution Strictly adhere to the specifications for I/O modules.
Connecting 5.2 Connecting the device to power 5.2 Connecting the device to power To be noted before you connect the device Note The long-range power supply module is designed for operation on 100-240 networks. It is not necessary to adjust the voltage range. Warning Do not connect or disconnect power and data cables during thunderstorms. Warning The device is designed for operation on grounded power supply networks (TN systems to VDE 0100, part 300, or IEC 60364-3).
Connecting 5.2 Connecting the device to power Localized information Outside of the USA and Canada, operation on a 230 V power supply: This device is equipped with a safety-tested power cord which may only be connected to grounded shockproof power outlet. If you choose not to use this cable, you must use a flexible cable of the following type: min. 18 AWG conductor cross-section and 15-A / 250-V shockproof connector.
Connecting 5.2 Connecting the device to power Secure the power plug You can secure the power plug in order to avoid unintentional disconnection of the power cord. Steps in securing the power plug 1 Remove the fastening screw (1) on the power supply module. 2 Power plug clamp (2) screw it to the power supply module Warning If the power plug is secured with a clamp, the power outlet must be freely accessible to allow the device to be easily removed from the mains.
Commissioning 6.1 6 Prerequisites for commissioning • Before you switch on the device, you should verify that the peripherals are connected, i.e. the keyboard, mouse, monitor and the power supply. • The operating system of your device is preinstalled on the hard disk. Caution Risk of damage to the device! Make sufficient allowances for the device to acquire room temperature before you put it into use. If condensation develops, wait at least 12 hours before switching on the device. 6.
Commissioning 6.3 Reinstalling the software From now on, after you switch on the PC, the user interface of the operating system is automatically opened when the startup routine is completed. Switch off the device Note On a Windows platform, always shut down the PC by clicking Start > Close. Press the on/off button behind the front panel door. The green power LED is switched off. Disconnect the mains connector to isolate the device from mains. 6.
7 Dimension drawings 7.1 Dimensional drawing of the device oben bei senkrechtem Einbau 465.1 18.31 176.5 6.94 101.6 4 483 19.01 oben bei senkrechtem Einbau Dimensions: Figure 7-1 19.39 17.68 492.54 449.04 433.5 17.
Dimension drawings 7.2 Dimensional drawing for the use of telescopic rails Dimensional drawing for the use of telescopic rails 100±T1 3.937±T1 100±T1 3.937±T1 Dimensions for telescopic rails by the company Rittal type 3659 100±T1 3.937±T1 72.6 ± T2 2.858 ± T2 33.54±T3 1.32±T3 127±T1 5±T1 Dimensions: T1=Tolerance ± Figure 7-2 7-2 209.6±T1 8.251±T1 355.6±T1 14±T1 mm Inch 0,1 mm 0.004 Inch T2=Tolerance ± 0,3 mm 0.01 Inch 88.5 ± T2 3.484 ± T2 7.
A Appendix A.
Appendix A.2 Certificates and approvals A.2 Certificates and approvals DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems.) EQ-Net certificate no.: 1323-01 Software License Agreement The device is shipped with preinstalled software.
Appendix A.3 Service and support EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Appendix A.3 Service and support Training center Siemens offers a number of training courses to familiarize you with the SIMATIC automation system. Please contact your regional Training Center, or the central Training Center in D90327 Nuremberg. Telephone: +49 (911) 895-3200. Internet: http://www.sitrain.com Technical Support You can reach Technical Support for all A&D products using the Web form for Support Request available under http://www.siemens.
Siemens AG Automation and Drives Industrial Automation Systems Postfach 4848 90437 NUERNBERG Federal Republic of Germany www.siemens.