Computer Drive Installation Instructions

7 Drive Machine Data (SIMODRIVE Drive MD) 12.93
7.1.2 MSD MD (data description - SW 3)
Motor no-load voltage motor 1
165
Default value Lower input limit Upper input limit Units
Depends on motor 0 500.0 V
Active on
Power On
Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor no-load current motor 1
166
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Stator resistance cold motor 1
167
Default value Lower input limit Upper input limit Units
Depends on motor 0 32 767 m
Active on
Power On
Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Rotor resistance cold motor 1
168
Default value Lower input limit Upper input limit Units
Depends on motor 0 32 767 m
Active on
Power On
Input of rotor resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Stator leakage reactance motor 1
169
Default value Lower input limit Upper input limit Units
Depends on motor 0 32 767 m
Active on
Power On
Input of stator leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Rotor leakage reactance motor 1
170
Default value Lower input limit Upper input limit Units
Depends on motor 0 32 767 m
Active on
Power On
Input of rotor leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
7–20 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)