Computer Drive Installation Instructions

12.93 7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Motor rated voltage motor 2
222
Default value Lower input limit Upper input limit Units
Depends on motor 0 500.0 V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated speed motor 2
223
Default value Lower input limit Upper input limit Units
Depends on motor 0 4 096 1/min
Active on
Power On
Input of motor rated speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated frequency motor 2
224
Default value Lower input limit Upper input limit Units
Depends on motor 0 409.6 Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor no-load voltage motor 2
225
Default value Lower input limit Upper input limit Units
Depends on motor 0 500.0 V
Active on
Power On
Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor no-load current motor 2
226
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Stator resistance cold motor 2
227
Default value Lower input limit Upper input limit Units
Depends on motor 0 32 767 m
Active on
Power On
Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–31