Computer Drive Installation Instructions

7 Drive Machine Data (SIMODRIVE Drive MD) 08.96
7.3.2 Drive MD (data description)
Upper speed L
h
characteristic motor 1
1143
Default value Lower input limit Upper input limit Units
0.0 0.0 50 000.0 rev/min
Active on
Power On
Input of upper speed limit for the L
h
characteristic (magnetizing inductivity L
h
) as specified on
the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing reactance X
n
increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L
h
characteristic (see diagram MD 1144).
Notes:
This machine data only applies to main spindle drives.
As from SW 5, this machine data is no longer used.
Gain factor L
h
-characteristic
1144
Default value Lower input limit Upper input limit Units
0.0 100.0 500.0 %
Active on
Power On
Input of gain factor (L
h2
/L
h1
) of the L
h
characteristic (magnetizing reactance) as specified on
the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing inductivity L
h
increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L
h
characteristic.
Graphic representation:
n
MD 1142
Rated value L
h1
n
L
h2
L
h
100 %
MD 1142 MD 1143
MD 1144
Notes:
If the value is unknown, then 100 % should be entered in order to obtain constant
magnetizing reactance over the entire speed range.
This data is relevant only for MSD drives.
As from SW 5, this machine data is no longer used.
7–96 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)