Computer Drive Installation Instructions

7 Drive Machine Data (SIMODRIVE Drive MD) 09.95
7.3.2 Drive MD (data description)
Specified: Blocking frequency 1 kHz, 500 Hz bandwidth and 250 Hz bandwidth numerator
(damping)
1 10Log 1k 10 kHz
20.0
0.0dB
-60.0
100
-5.0
Blocking frequency
1 10Log 1k 10 kHz
180
Deg
-180
100
Type current setpoint filter
1201
Default value Lower input limit Upper input limit Units
Low-pass Low-pass Band-stop
Active
at once
Input of configuration of 4 current setpoint filters. Band-stop and low-pass filters are available.
The adjustable filter parameters are entered in the appropriate machine data.
Value table:
1st filter Bit 0
0
1
Low-pass (see MD 1202/1203)
Band-stop (see MD 1210/1211/1212)
2nd filter Bit 1
0
1
Low-pass (see MD 1204/1205)
Band-stop (see MD 1213/1214/1215)
7–102 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)