7.3.2 Drive MD (data description)
Block frequency speed setpoint filter 1
1514
Default value Lower input limit Upper input limit Units
3 500.0 1.0 7 999.0 Hz
Active
at once
Input of block frequency for speed setpoint filter 1 and parameterization as simple band-stop
filter. The filter is activated via machine data MD 1500 (number of setpoint filters) and MD
1501 (type speed setpoint filter). The machine data MD 1516/MD 1519 (bandwidth numerator
speed setpoint filter) and MD 1520/MD 1521 (band-stop filter natural frequency speed setpoint
filter) keep their default values.
Formula:
1+s · (2 · · fbz/(2 · · fz)
2
)+s
2
· 1/(2 · · fz)
2
H(s) = ––––––––––––––––––––––––––––––––––––––––––––––––
1+s · (2 · · fbn/(2 · · fn)
2
)+s
2
· 1/(2 · · fn)
2
Input:
fz = MD 1514/1517 Blocking frequency speed setpoint 1/ speed setpoint 2 [Hz], (point
of resonance)
fbn = MD 1515/1518 Bandwidth denominator filter 1/filter 2 [Hz]
fbz = MD 1516/1519 Bandwidth numerator filter 1/filter 2 [Hz]
fn = MD 1520/1521 Band-stop filter natural frequency filter 1/filter 2 [%] percentage with
reference to MD 1514 or MD 1517
MD 1520 (MD 1521)
fn = –––––––––––––––––––· MD 1514 (MD 1517) [%]
100
Example:
20.0
dB
-60.0
5
Polynomial
4 kLog Hz
180
Phase
Deg
-180
fz = 900 Hz MD 1514/1517
fbn = 600 Hz MD 1515/1518
fbz = 0 Hz MD 1516/1519
(Default value)
fn = 100 % MD 1520/1521
(Default value)