Computer Drive Installation Instructions

09.95 7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Machine data which correspond to this machine data are as follows:
Signal number variable message function (MD 1621)
Address variable message function (MD 1622)
Threshold variable message function (MD 1623)
Hysteresis variable message function (MD 1624)
Pickup delay variable message function (MD 1625)
Delayed dropout variable message function (MD 1626)
Note:
Changes to inputs in machine data MD 1621 to MD 1624 while the monitoring function is
already active (MD 1620 - bit 0 = 1) do not automatically result in re-initialization, i.e. reset to
zero, of message bit 5. If a bit reset is required, the monitoring function must be deactivated
and then re-activated by means of MD 1620, bit 0, after the machine data has been altered.
Signal number variable message function
1621
Default value Lower input limit Upper input limit Units
0 0 100
Active
at once
Input of signal number of memory location to be monitored via the variable message function.
©