Computer Drive Installation Instructions

09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50
4–27
SINUMERIK 840C (IA)
4.4.2.2 Value ranges and default values
Keyword Value range Default value
LANGUAGE String of max. 8 characters “DEUTSCH”
BT_NAME String of max. 8 characters “SER:”
PROTLEN1 1 32767 (with PROTMODEDISK) 25
PROTLEN2 1 32767 (1200 without
PROTMODEDISK)
25
FLUSHLEN1 0 .. 10 0
FLUSHLEN2 0 .. 10 2
FLUSHTIME 0.1 32767 0
PROTMASK
1
)
Special format K = OT < 4
K > 0
PROTMASK2 Special format T < 2
PRIO_PO
1
)
10
PRIO_RE
1
)
110
PRIO_CA
1
)
210
PRIO_PA
1
)
0,1 < 32000
310
PRIO_PM
1
)
350
PRIO_KO
1
)
510
SYSFONT
2)
0, 1, 2 0
TFORMAT String of max. 20 characters, see
above
hh:mm:ss DD.MM.YY
Language This defines the language.
The possible languages are:
S DEUTSCH
S ENGLISH
S ITALIANO
S FRANÇAIS
S ESPAÑOL
The default setting is DEUTSCH (upper case mandatory).
For certain software versions, SWEDISH, RUSSIAN and HUNGARIAN are
available.
SYSFONT With SW 4.4 and higher, the character set is defined by an entry in the
<character set number> configuration file of the master control.
Possible character set numbers:
0 Standard character set
1 Cyrillic character set
2 Character set for Slavonic languages (and Hungarian)
3 Portuguese
With SW 5.* and higher, the SYSFONT is stored in the system when selecting
the language.
4 MMC Area Diagnosis
4.4.2 Configuration file CONFIG
09.01
1) Up to SW 2 only
2) SW 4.4 and higher