Technical information

Technical Description
SIMpad SL4
Version V2.0
Siemens AG 10/74
ICM CP 20.08.01, David Brunner
The various types of reset are listed in the table below. For instance, the soft reset is
done after new software is installed.
Reset Triggered by Effect
Software reset application; can be
triggered from start
menu (see 5.4.11)
Initialised system processes (running
programs are ended)
Object store and RAM registry are not
affected
Hardware reset:
Warm start
reset switch (see 1.1) Persistent registry loaded
Object Store and Program Memory are
retained
Hardware reset:
Cold start
reset switch plus right
mouse button (see 1.1)
The whole of RAM is deleted, including
Object Store and Program Memory
Persistent registry loaded
Hardware reset:
“Factory reset”
(state as supplied)
reset switch plus right
mouse button plus soft
keyboard button. Keep
the two buttons pressed
at least 5 seconds (see
1.1)
RAM and persistent registry are deleted
Image is rebooted (see 2.4.1)
SIMpad is back in state as supplied
1
and will
restart with a first start (see 5.2.3)
1