Technical information

Technical Description
SIMpad SL4
Version V2.0
Siemens AG 67/74
ICM CP 20.08.01, David Brunner
Upper temperature +60 °C, 72 hours
Temperature cycling -20 °C / +30 °C at 1 °C/min, 5 cycles, 1 hour pause
Vibration Noise, 1 m
2
/s
3
, 10 - 200 Hz, 3 x 10 min
Shock 6 x 500 shocks, 400 m/s
2
, 6 ms
Free fall 1.2 m onto wood, 6 x 1 fall
6.3.3 Storage
Storage class ETS 300 019-1-1, Class 1.1
Storage condition Device in its original packing, not in operation
Temperature range -5 ° ... +55 °C
Relative humidity 5 % ... 95 %
These requirements are less than for transport, and consequently they are satisfied.
6.3.4 Operation
Operating class ETS 300 019-2-3, Class 3.1
Operating condition Device open and in operation, but can also fail briefly
Temperature +5 ° ... +40 °C
Relative humidity 5 % ... 85 %
Test conditions
Lower temperature +5 °C, 16 hours
Upper temperature +40 °C, 16 hours
Temperature cycling +25 °C / +40 °C at 0.5 °C/min, 5 cycles, 3 hours pause
Relative humidity +30 °C / 85 % rel. humidity, 4 days
Humidity change None
Vibration None
Shock 6 x 3 shocks, 50 m/s
2
, 6 ms
Free fall 20 cm onto wood