Specifications

SINAMICS G150 NEMA
Introduction
1
Siemens D11.7 (Part 1) – 2013
1/6
SINAMICS G150 – A Global Product
SINAMICS G150 is a global product. However, regional
differences in regulations, standards, specifications and
voltage levels for power and control require modifications
to the packaging (enclosure) and auxiliary components.
SINAMICS G150 enclosed drives are therefore offered in
versions designed to IEC (European) as well as to NEMA
(North American) standards.
SINAMICS G150 designs to NEMA vs. to IEC standards
All models of SINAMICS G150 (NEMA or IEC, type A or type
C) use the identical basic drive and electronics components
– power module of a particular power and voltage rating,
CU320-2 control unit, CompactFlash card with firmware,
AOP30 operator panel and TM31 input/output module as
well as optional modules (SMC30 encoder interface, VSM10
voltage sensing module, CBE20 PROFINET communications
module, etc.).
Differences between the NEMA and IEC versions are found
in the configuration of the base units, i.e. the enclosure type
and the scope of auxiliary equipment/options included, as
well as the offered range of standard and custom options.
Below is an overview of some of the more significant
differences between NEMA and IEC versions (not a
complete list!).
SINAMICS G150 NEMA SINAMICS G150 IEC
Type A enclosed drive Ver. A cabinet unit
Base unit enclosure NEMA 1 (equivalent to IP21 with top hat/ IP20 (no roof - air discharge upwards)
and configuration roof – air discharge front and back)
Included in base for all ratings: Included in base:
• Circuit breaker disconnect per NEC/UL for Input line reactor only for ratings
motor branch circuit protection. <500 kW – optional for >500 kW
Molded case circuit breaker (type VL) EMC filter Category C3 for 2
nd
environment
Fixed mounted fuses to meet SCCR (industrial) per IEC 61800-3
SCCR per UL508A: 65 kA for 480 V, 25 kA to
35 kA for 600 V units EXCLUDED from base (requires option code):
Input line reactor Fused disconnect (for <800A) or circuit
Ground bus breaker (for >800A, with 3WL motorized
• Terminal module TM31 with digital and analog I/O circuit breaker). Note this option is not per
Touch safe covers NEC/UL for motor branch circuit protection.
EMC filter Category C3 for 2nd environment
(industrial) per IEC 61800-3
Enclosure options NEMA 1 filtered with louvers and dust filters IP21 (with raised roof)
(equivalent to IP 23) IP23 (with top hat, louvers and dust filters)
IP43 as for IEC unit IP43 (like IP23, plus 1mm mesh screen)
• NEMA 12 (ventilated) – louvers and fine • IP54 (like IP23, plus fine air filters)
air filters (equivalent to IP54)
Other standard Input contactor option for all ratings Input contactor option for <800 A – higher
options • Mechanical door interlock option (slam latch) ratings use 3WL breaker as switching device
Exclusive standard Only for NEMA version: Only for IEC version:
options • UL/cUL listing per UL508A Marine version, and individual marine
• Bypass circuits certification by ABS, DNV and others
• EMC filter Category C2 for 1st environment
(residential) per IEC 61800-3
SINAMICS G150 NEMA SINAMICS G150 IEC
Type C enclosed chassis Ver. C cabinet unit
Base unit enclosure NEMA 1 (equivalent to IP21 with top hat/ IP20 (no roof - air discharge upwards)
and configuration roof – air discharge front and back)
Included in base for all ratings: Included in base:
• Ground bus • Input line reactor only for ratings
SCCR 65 kA @ 480 V, 35 kA @ 600 V when used <500 kW – optional for >500 kW
with the required protective devices
EMC filter Category C3 for 2
nd
environment • EMC filter Category C3 for 2
nd
environment
per IEC 61800-3 per IEC 61800-3
EXCLUDED from base (requires option):
Input line reactor
Other standard Enclosure options as for type A above Enclosure options as for Ver. A above
options • UL/cUL listing per UL508A UL listing per UL508A (SCCR 10kA)
Marine version and certifications as above