Specifications

SINAMICS G150 NEMA
Engineering information
4
Siemens D11.7 (Part 1) – 2013
Derating data
4/4
Current derating as a function of the pulse frequency
If the drive is set to operate at increased pulse frequencies,
the output current values listed in the technical specifications
must be derated in accordance with the tables below.
(Note that SINAMICS G150 can be set up to operate at
higher pulse frequencies when permitted by ambient
and load conditions, and automatically lower the pulse
frequency to avoid overtemperature – in this case derating
is not necessary).
Order no. Output
(light overload)
at 460 V or 575 V, 60 Hz
Rated output current at 2 kHz
Derating factor at 4 kHz
HP A
Supply voltage 380 V to 480 V 3 ph. AC
6SL3710-1GE32-1_U3 150 210 82 %
6SL3710-1GE32-6_U3 200 260 83 %
6SL3710-1GE33-1_U3 250 310 88 %
6SL3710-1GE33-8_U3 300 380 87 %
6SL3710-1GE35-0_U3 400 490 78 %
Derating factor of the output current as a function of the pulse frequency for devices with a rated pulse frequency
of 2 kHz
Derating factor of the output current as a function of the pulse frequency for devices with a rated pulse frequency
of 1.25 kHz
Order no. Output
(light overload)
at 460 V or 575 V, 60 Hz
Rated output
current at 1.25 kHz
Derating factor
at 2.5 kHz
Derating factor
at 5 kHz
HP A
Supply voltage 380 V to 480 V 3 ph. AC
6SL3710-1GE36-1_U3 500 605 72 % 60 %
6SL3710-1GE37-5_U3 600 745 72 % 60 %
6SL3710-1GE38-4_U3 700 840 79 % 60 %
6SL3710-1GE41-0_U3 800 985 87 % 60 %
Supply voltage 500 V to 600 V 3 ph. AC
6SL3710-1GF31-8_U3 150 175 87 % 60 %
6SL3710-1GF32-2_U3 200 215 87 % 60 %
6SL3710-1GF32-6_U3 250 260 88 % 60 %
6SL3710-1GF33-3_U3 300 330 82 % 55 %
6SL3710-1GF34-1_U3 400 410 82 % 55 %
6SL3710-1GF34-7_U3 450 465 87 % 55 %
6SL3710-1GF35-8_U3 600 575 85 % 55 %
6SL3710-1GF37-4_U3 700 735 79 % 55 %
6SL3710-1GF38-1_U3 800 810 72 % 55 %
Calculating derating factor by means of linear interpolation.
For intermediate values of pulse frequencies, the relevant derating factors can be determined by means of linear interpolation.
The following formula applies to this:
Y
2
= Y
0
+
Y
1
– Y
0
(X
2
– X
0
)
X
1
– X
0
Example:
The derating factor is required for when X
2
= 2 kHz for 6SL3710-1GE41-0_U0.
X
0
= 1.25 kHz, Y
0
= 100% X
1
, = 2.5 kHz
,
Y
1
= 87%, X
2
= 2 kHz, Y
2
= ??
Y
2
= 100% +
87% – 100%
(2 kHz – 1,25 kHz) =
2.5 kHz - 1,25 kHz
100% +
-13 %
(0,75 kHz) = 100 % – 7,8 % = 92.2 %
1,25 kHz
Derating factor
100%
??%
75%
50%
25%
1,25 kHz 2 kHz 2.5 kHz 5 kHz f
Pulse
87%
60%