Planning Tool – fi re safety solutions for data centers
Point type fi re detectors
ASAtechnology offers unsurpassed detection
reliability with high immunity to deception.
Therefore, a Genuine Alarm Guarantee can be
offered.
2
Video surveillance
The video surveillance system monitors critical
zones such as the entrance area etc. to record
incidents before and after an event.
9
Intrusion detection
Detection of unauthorized access. Siemens offers
a complete range of devices for each kind of
risk and application. For the protection against
ooding, a special fl ood detector enables the
alarm system to detect water leaks.
11
Alarm indicators
If a fi re detector that is not easily visible triggers
an alarm, the alarm indicator will quickly identify
the area in danger.
4
Ex zone devices
To guarantee continuity in case of power failure,
a data center is always connected to an uninter-
ruptible power supply (UPS). In some of these
explosion-hazard areas, such as battery rooms
or gas generators, Ex devices have to be used.
13
Voice alarm system
In case of a fi re, the voice alarm system E100 is
automatically activated by the fi re detection
system. It ensures that the data center and neigh-
boring areas are evacuated before the discharge
of an extinguishing agent.
6
Extinguishing control panels
XC10 combines fi re detection and extinguishing
control – either for a single-sector or a multi-sector
application. All relevant incidents are forwarded to
connected fi re control panels. It also interfaces with
ventilation systems.
3
Access control
The access control system provides safe and
exible access authorization, time recording,
and badge issuing.
10
Extinguishing with Sinorix CDT
Recommended for medium- to large-sized data
centers, Sinorix CDT enables effi cient extinguish-
ing without pressure peaks. Overpressure fl aps
can be reduced by up to 70%.
8
Extinguishing with Sinorix 1230
For small- to medium-sized data centers, Siemens
recommends Sinorix 1230 based on 3M™ Novec™
1230 Fire Protection Fluid. It fl oods the room within
10 seconds and starts extinguishing before any
electronic equipment is severely damaged.
8
Extinguishing with Sinorix H
O Gas
In critical applications uninterrupted power supply
(UPS) systems ensure continuity in case of power
cuts. For those systems representing a thermal
risk, Sinorix H
O Gas, based on nitrogen and water,
combines highly effi cient nitrogen extinguishing
with a cooling water mist.
12
* The Sinorix Silent Nozzle will be available soon.
Aspirating smoke detection
The highly sensitive system for the earliest possible
re detection in highly ventilated data centers
minimizing the risk of fi re damage. It is typically
applied in closed server racks, false fl oors, and
ceilings, cable ducts and air in- and outputs.
1
Sinorix Silent Nozzle
The silent discharge nozzle technology is at the
core of our new Sinorix Silent Nozzle*. It ensures
quiet and effective extinguishing in data centers
and server rooms.
7
Fire control panels
The Sinteso fi re control panels convert a fi re alarm
into actions for alarm notifi cation, evacuation,
and extinguishing. The simple user interface with
prompting texts lets users quickly check the system
status, either locally or by remote access.
Siemens Switzerland Ltd
Infrastructure & Cities Sector
Building Technologies Division
International Headquarters
Gubelstrasse 22
6301 Zug
Switzerland
Tel +41 41 724 24 24
The information in this document contains general descriptions of technical options available,
which do not always have to be present in individual cases. The required features should therefore
be specified in each individual case at the time of closing the contract.
Novec™ 1230
Fire Protection Fluid
3M and Novec are trademarks of 3M Company.
© Siemens Switzerland Ltd, 2011
growing. For our customers, success is defined by how
well they manage these challenges. Siemens has the
answers.
We are the preferred partner for energy-efficient,
safe, and secure buildings and infrastructure.”
Answers for infrastructure.
Our world is undergoing changes that force us to think
in new ways: demographic change, urbanization, global
warming, and resource shortages. Maximum efficiency
has top priority – and not only where energy is concerned.
In addition, we need to increase comfort for the well-being
of users. Also, our need for safety and security is constantly
Fire safety solutions
for data centers
Planning Tools
Sounder and sounder beacon
In a data center, the alarm sounder FDS221 and
alarm sounder beacon FDS229 are recommended
to alert the occupants acoustically and optically.
5

Summary of content (2 pages)