Computer Drive Installation Instructions

6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.3 Channel-specific MD (channel data)
Reset state G group
108*-122*
Default value Lower input limit Upper input limit Units
see below
see table of input
values
see table of input
values
Active in block
prior
to
decodg
The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.
Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.
The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.
Default value
T M G group
108* 1 1 1
110* 18 17 3
112* 54 54 6
114* 64 60 8
116* 0 0 9
118* 95 94 12
120* 150 150 15
122* 450 450
1)
25
Table of input values
Internal
G group
G functions
0
00
MD
01
M/T
MD
10
MD
11
MD
02
MD
03
MD
33
MD
34
MD
35
MD
06
MD
12
MD
13
MD
36
MD
1 09
2
17
M
MD
18
T
MD
19
MD
16
3
40
M/T
41 42
4 53
5
54
M/T
MD
55
MD
56
MD
57
MD
6 04 25 26 58 59 92 74
7
60
M
MD
63
MD
64
T
MD
62
MD
8 70 71
_______
1) As from SW 2
6–32 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50