Computer Drive Installation Instructions

10.94 7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Motor moment of inertia motor 1
159
Default value Lower input limit Upper input limit Units
Depends on motor 0.002 32.000 kgm
2
Active on
Power On
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated power motor 1
160
Default value Lower input limit Upper input limit Units
Depends on motor 0 150.0 kW
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated current motor 1
161
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor rated current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated voltage motor 1
162
Default value Lower input limit Upper input limit Units
Depends on motor 0 500.0 V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated speed motor 1
163
Default value Lower input limit Upper input limit Units
Depends on motor 0 4 096 rev/min
Active on
Power On
Input of motor rated speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Motor rated frequency motor 1
164
Default value Lower input limit Upper input limit Units
Depends on motor 0 409.6 Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50 7–19