1 Basic information....................................................................................5 2 2.1 Access modes .........................................................................................5 Tag types ..................................................................................................5 3 3.1 3.2 Badge type...............................................................................................6 User badge.......................................................
Basic information 1 Basic information SiPass standalone is a complete access control system for one door and up to 500 cardholders. SiPass standalone uses 125 kHz proximity technology. For gaining access, it is sufficient to hold the badge close to the reader. For programming purposes, an optional Remote Programmer can be used, which is simply held close to the reader the same way as a user badge. No wiring connection is required.
Badge type 3 Badge type 3.1 User badge User Can be used in ”Access” mode only. Special Can be used in both, ”Access” and ”Night lock” mode. 3.2 Master badge Program Master Master of masters Add Master Allows to introduce new badges to the systems memory Void Master Allows to delete (void) badges from the systems memory Night lock master Switches the system from access mode to night lock mode and back. 6 Siemens Building Technologies Fire Safety & Security Products 02.
LED indicators 4 LED indicators Read indication (yellow) Open (green) Closed (red) Night lock (red) Add (red) Void (red) Program (red) Fig. 1 5 LED indicators Overall time-out In Program Mode, after 30 seconds of inactivity, an error tone sounds, and normal operation resumes. 7 Siemens Building Technologies Fire Safety & Security Products 02.
Security measures 6 Security measures 6.1 Missing tag For safety precautions the user is strongly advised to keep records of the ID numbers and functions of all badges and the names of their users. In case of loss, the specific badges can be voided from memory by entering the badge number on the SiPass standalone Remote Programmer. See Appendix. 6.2 Anti tamper A tamper alarm is triggered if the unit is ripped off the wall. 6.
Wake up: Declaring the Program Master 7 Wake up: Declaring the Program Master When powering up a SiPass standalone for the first time, one selected badge must be presented, to be declared as the Program Master. The Program Master may be regarded as a kind of master of masters; it will be instrumental in enabling all other masters and badges.
Declaring the masters 8 Declaring the masters SiPass standalone has 3 programming modes which need to be processed before normal operation. When going through these modes the first time, you can directly declare the respective masters.
Change Program Master 9 Change Program Master This procedure replaces the old Program Master by a new one. The old Program Master is thereby voided from the SiPass standalone memory and the new badge is declared as Program Master instead. This is helpful if e.g. an other Program Master than the normal one was added to the memory during wake-up. Present the new Program Master a further 5 times to step through the remaining steps, back to Normal mode.
Add new user badge 10 Add new user badge Badges which shall be granted access must first be stored in the SiPass standalone memory. The Add Master allows new badges to be added which, from then on, will be granted access. Any badge can be added, except Master badges and badges which are already in memory.
Void user badge 11 Void user badge Badges which shall be denied access must first be voided from the SiPass standalone memory. The Void Master allows badges to be voided which, from then on, will be denied access.
Set Night Lock Mode 12 Set Night Lock Mode In night lock mode, normal badges will not be granted access. Only Special User Badges are granted access in this mode. Night Lock Mode is switched on with the Night Lock Master Night Lock Mode Normal operation Read Open Closed Night lock Add Void Program Fig. 7 Read Open Closed Night lock Add Void Program Night Lock Master Set night lock In case of power failure, SiPass standalone will memorize the current status of the Night Lock.
Unset Night Lock Mode 13 Unset Night Lock Mode Only the Night Lock Master can switch Night Lock off. When presenting the Night Lock Master to unset Night Lock, access is granted at the same time. This function is intended for persons who are authorized to enable access for others, for example to unlock an office building in the morning.
Add Special User Badge 14 Add Special User Badge Special User Badges are granted access both, during Night Lock and during Normal Operation. Unlike the Night Lock Master, they have no effect on Night Lock status. Special User Badges must be added by using the Add Master while SiPass standalone is in Night Lock mode.
Declare Remote Programmer 15 Declare Remote Programmer To store a Remote Programmer in the SiPass standalone memory, first show the Program Master to enter Program mode, then present the Remote Programmer while in Program mode. After this, SiPass standalone will resume its normal operation. Normal operation Read Open Closed Night lock Add Void Program Enter Program Mode Read Open Closed Night lock Add Void Program Program Master Fig.
Void badge with a Remote Programmer 16 Void badge with a Remote Programmer Using a Remote Programmer, badges or Remote Programmers can be voided by their number. This is useful if badges or Remote Programmers are lost, stolen or damaged beyond use. For this reason it is important to keep records of all added badges, Masters and Remote Programmers. 1 9 Read Open Closed Night lock Add 2 3 Void Program 4 5 6 7 8 9 * 0 # Void Mode Enter Void Mode Program Mode Fig.
Appendix 17 Appendix 17.1 Tag registration list ID Number Date Masters Program Master Void Master Add Master Nightlock Master Remote Programmers Users 19 Siemens Building Technologies Fire Safety & Security Products 02.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.sbt.siemens.com Document no. A24205-A335-B241 Edition 02.2005 © 2005 Copyright by Siemens Building Technologies AG Data and design subject to change without notice. Supply subject to availability. Printed in the Federal Republic of Germany on environment-friendly chlorine-free paper.