Instruction manual

7ML19985CL02 SITRANS LR 300 – INSTRUCTION MANUAL Page 9
mmmmm
Specifications
Sanitary Antennas (FDA approved materials):
dielectric rod: one piece UHMW-PE; optional PTFE
2”, 3”, 4” tri-clamp connection
horn: 304 stainless steel
horn with integral 4” tri-clamp connection
PTFE emitter
Enclosure (electronic):
construction: aluminum, epoxy-coated; or 316 stainless steel
conduit: 2 x 1/2" NPT or M 20 x 1.5 entry
ingress protection: Type 4X / NEMA 4X, Type 6 / NEMA 6, IP 67: (see note
below)
Weight:
7.5 kg (16.5 lb) with 2"/150 psi flange (aluminum); 13.6 kg (30 lb) stainless steel
weight will vary with flange size and rating
Environmental:
location: indoor/outdoor
altitude: 2000m max.
ambient temperature: 40 to 60° C (40 to 140° F)
1
relative humidity: suitable for outdoor
installation category: II
pollution degree: 4
1.
See Appendix III (Ambient/Operating Temperature Specification) on page 101, and
Approvals on page 10
WARNING: Materials of construction are chosen based on their
chemical compatibility (or inertness) for general purposes. For
exposure to specific environments, check with chemical
compatibility charts before installing.
Notes:
•See Appendix III, Ambient/Operating Temperature Specification on page 101,
and Approvals on page 10, for the specific configuration you are about to use or
install.
The use of approved watertight hubs/glands is required for Type 4X / NEMA 4X, Type
6 / NEMA 6, IP 67 (outdoor applications).