Parameters
Volume Parameters (P050 to P055)
Set the SITRANS LR 300 to calculate readings based on reservoir volume rather than
level.
P050 Tank Shape (F = 0)
Enter the Tank Shape value that matches the monitored vessel or reservoir. (See chart on
next page.)
When Operation is LEVEL (P001 = 1), liquid (material) volume is calculated. When
Operation is SPACE (P001 = 2), remaining vessel capacity is calculated
In the RUN
mode, readings are displayed in volumetric units. (See Maximum Volume
[P051] on page 60.) When percent is selected, the displayed volume reading is a
percentage of Maximum Volume.
Note: Parameters P052 and P053 set tank dimensions A and L.