User Manual

Siemens Data Sheet 2592
Building Technologies Division usa.siemens.com/fire
Product Overview
Siemens is now offering low-frequency sounder-strobes to its notification-
appliances portfolio. Formed as the `SL-series, these technologically
advanced sounder-strobes meet National Fire Protection Association (NFPA)
requirements for recognized sleeping areas within a commercial building:
NFPA-72 for fire alarm
NFPA-72 for Carbon Monoxide (CO) alarm
In a single device, the `SL-series can provide
alarm-signaling tones for dual applications:
Temporal 3 pattern, (T3 FIRE)
Temporal 4 pattern, (T4 CO)
Additionally, each Model `SLsounder-strobe has an advanced, power-saving
light-emitting diode (LED) technology with three (3) modes of 520 Hertz
operation (for the sounder portion of these notification appliances)
T3 FIRE
T4 CO
Continuous (coded) dual-sync (T3 / T4) control for FIRE and CO signaling
Synonymous to the current Siemens `LFS’-series of sounder-only notification
appliances, the `SL-series of sounder-strobes are produced in a sleek, modern
design. Its fitting provides high-quality energy efficiency in an aesthetically
pleasing, low-profile design that is consistent to the look of the interior
composition of the building application.
The inclusive trim plate makes for easy installation for retrofit projects that
already have backboxes installed. The `SL-series is apt for indoor wall-mount
applications. Moreover, the Series `SLFS’ and `SLFSS models, which operate on
24VDC, are designed specifically for indoor, wall-mount applications.
Notification Appliances
`SLFS’ and `SLFSSSeries Low-Frequency
Sounders | Sounder-Strobes
Applications : Indoor, Wall-Only
Model SLFSSWR-N+
Sounder-strobe
Architect & Engineer Specifications
Sophisticated series of notification
appliances that meets fire-industry codes
and regulations for commercial-building
applications
Compatible with the Siemens 50-point, 252-
point and 504-point addressable fire alarm
control panels (FACPs), and with:
- Siemens Modular FACPs
- Siemens PAD-series of NAC extenders
- FireFinder® XLS / XLSV FACPs
- Siemens dual-sync control (DSC) modules
Innovative LED strobe technology provides an
energy-efficient means for a significantly
reduced current draw
- Means to have existing Xenon and new LED
strobes in the same field-of-view
- 110cd Candela setting for Model `SLFSS-
series sounder-strobes
- 110cd” is labeled on the outer edge,
right-hand side, just above the temporal-
setting adjustor
Straightforward installation coupled with
compact, modern design
- Built-in level adjustment component with
snap-on grille front cover
- Manual (index finger) slide-
setting adjustor
Four (4) temporal-pattern settings in each
notification appliance
- `T3’ (for FIRE) setting
- `T4’ (for CO) setting
- Continuous (coded) dual-sync setting
(`T3 / `T4’) for FIRE with CO
Dual, low-frequency sounder codes in
each appliance
- Meets NFPA-72 for Fire-Alarm and
Carbon Monoxide
UL (2034 | 1971 | 464) Listed,
ULC (-S525 | ULC-S526) Listed
- ADA | NFPA | ANSI | OSHA compliance
Model SLFSSWW-N+
Sounder-strobe

Summary of content (4 pages)