Specifications

15
Engineer programming via the browser
Configuring communications
226
Siemens AB
A6V10276959
Security Products
18.11.2011
has been changed.
Reporting Timer
Enter the minutes how long after the last configuration change the
panel should contact the server to report its configuration ( min: 1,
max.: 120 ).
Enable IP
Tick this box to enable a connection to the panel using Internet
Protocol (IP).
TCP/IP Port
Enter the IP port that SPC Safe will use to connect to the panel (the IP
port of the panel).
Server address
Enter the Hostname, URL or IP address of the SPC Safe server (e.g
the IP address of your PC).
Server TCP/IP Port
Enter theTCP port of the SPC server (e.g .the IP port of your PC).
15.12.7 Alarm Reporting Centres (ARCs)
The SPC panel has the facility to communicate information to a remote receiving
station when a specific alarm event on the panel has occurred.
These Alarm Reporting Centres must be configured on the panel to allow this
remote communication to operate.
15.12.7.1 SIA codes
SIA (Security Industries Association) codes are an industry standard format for
reporting detailed information on alarm events to a remote central station. Each
code consists of a 2 letter identifier that is interpreted by the central station
according to the list below.
An address field (zone or user number) is also included with some of the codes
listed to give more accurate information on the event; e.g. the SIA code BA5 refers
to a burglary alarm event on Zone 5.
For a full listing of codes, see page [➙ 273].
15.12.7.2 Adding / Editing an ARC
A PSTN or GSM modem is installed and functioning correctly.
1. Select Settings > Comms > ARC.
The following window will be displayed:
2. Click on the Modem1/2 button to make a test call to the ARC from the either
modem 1 or modem 2.