Specifications

Engineer programming via the keypad
14
X-BUS
83
Siemens AB
A6V10276959
Security Products
18.11.2011
1
1
2
3
4
7
5
0
9
8
6
1
2
3
4
7
5
0
9
8
6
Rotary switches identifying expander as 38
For a system with automatic addressing, expanders and keypads belong to the
same numbering sequence. E.g. expanders and keypads are automatically
numbered 01, 02, 03, etc., by the controller in the order in which they are detected,
e.g. its relevant location to controller. In this configuration, zones are allocated to
each input expander.
Automatically addressed expanders are not supported by SPC41xx.
14.5.2 RECONFIGURE
NOTICE
A reconfigure only applies to wired zones on an expander. Wireless zones on an
expander and controller zones will not be brought online after a reconfigure. To
bring controller zones online, you must apply a zone type other thanUnused
using the zones menu on the keypad or web browser.
If the system has a mixture of expander types (with and without rotary switches)
then the system can only be automatically reconfigured. If the system has all
expanders with rotary switches, the system can still be automatically reconfigured
and the system will ignore the rotary switches and auto addresses all the
expanders on the system.
To reconfigure keypads/expanders:
1. Scroll to RECONFIGURE.
2. Press SELECT.
The number of online keypads is displayed.
3. Press NEXT.
The number of online expanders is displayed.
4. Press NEXT
The number of online zones is displayed.
5. Press BACK to exit.