Camera Accessories User Manual

Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : LRQ 0960094/A
Registration Date : March 3, 1995
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
s
Always connect the instrument to the specified power supply
voltage. Improper connection may cause a fire or electric shock.
SAFETY PRECAUTIONS
9242-4897-10 BCJEPK 5
Displays shown are for illustration purpose only.
The specifi cations and drawings given here are su
bject to change without prior notice.
KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "Giving Shape to
Ideas" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC.
The basICColor logo is a registered trademark of basICColor GmbH.
Other company names and product names used herein are trademarks or registered trademarks
of their respective companies.
©2010 KONICA MINOLTA OPTICS, INC.
DIMENSIONS
(Units: mm)
With removable target mask attached
171.5
165
84.2
90
70
25
φ6.2
Streamlines color adjustment
in printing, even on substrates
with  uorescent whitening agents
Density
Color
Illumination
Spectrodensitometer
FD
-
7/FD
-
5
3-in-1 next-generation measurement tool
Main specifi cations
Model FD-7 FD-5
Illumination/viewing system
45°a: 0°(annular illumination)

Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for refl ectance measurements.
Spectral separation device Concave grating
Wavelength range
Spectral refl ectance: 380 to 730 nm; Spectral irradiance: 360 to 730
nm
Spectral refl ectance: 380 to 730 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Measurement area Ø3.5mm
Light source LED
Measurement range Density: 0.0D to 2.5D; Refl ectance: 0 to 150%
Short-term repeatability
Density:
σ
0.01D
Colorimetric: Within
σΔ
E00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
Inter-instrument agreement
Within
Δ
E00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard
conditions)
Measurement time Approx. 1.4 s (single-point refl ectance measurement)
Displayed values
Colorimetric values, color-difference values, density values,
density-difference values, dot area ratio, dot gain, PASS/FAIL
judgment, illuminance, correlated color temperature
Colorimetric values, color-difference values, density values, density-
difference values, dot area ratio, dot gain, PASS/FAIL judgment
Measurement conditions
Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut
lter); User-defi ned illuminant
Illuminants A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defi ned illuminant
Observers 2° Standard Observer, 10° Standard Observer
Color spaces L
a
b
, L
C
h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces
Color-difference equations
Δ
E
ab (CIE 1976),
Δ
E
94 (CIE 1994),
Δ
E00 (CIE 2000),
Δ
E (Hunter), CMC (l:c)
Indexes WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index
Density ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536
Storable data Colorimetric target data: 30 data; Density target data: 30 data
Display language English, French, German, Spanish, Japanese, Chinese (Simplifi ed)
Scanning measurements

Scanning measurement of a color chart can be performed. N/A
Interface USB 2.0
Output data

Displayed values; Spectral reflectance data; Spectral irradiance
data
Displayed values
Power Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power
Dimensions (W × D × H) 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)
Weight Approx. 350g (Body only); Approx. 430g (With target mask attached)
Operating temperature/
humidity range
10 to 35°C, 30 to 85% relative humidity with no condensation
Storage temperature/humidity
range
0 to 45°C, 0 to 85% relative humidity with no condensation
1 Illumination for wavelengths under 400nm is unidirectional.
2 Available when using PC software.