Technical data

Table Of Contents
DPV1 SFBs According to PNO AK 1131
System Software for S7-300/400 System and Standard Functions - Volume 1/2
8-12
A5E00709327-01
Byte Data type Meaning
24 to 25 WORD Interrupt specifier:
Bits 0 to 10: Sequence number (range of values: 0 to 2047)
Bit 11: Channel diagnostics:
0: No channel diagnostics available
1: Channel diagnostics available
Bit 12: Status of manufacturer-specific diagnostics :
0: No manufacturer-specific status information available
1: Manufacturer-specific status information available
Bit 13: Status of diagnostics for interface module:
0: No status information available; all errors corrected
1: Diagnostics for at least one channel and/or status information available
Bit 14: Reserved
Bit 15: Application Relationship Diagnosis State
- 0: None of the configured modules within this AR is reporting a
diagnosis
- 1: At least one of the configured modules within this AR is reporting a
diagnosis
Structure of Additional Interrupt Information with Interrupts from PROFINET IO,
Case 1
The additional interrupt information for PROFINET IO depends on the format
identifier. If manufacturer-specific information is to be transmitted, the IO device
uses the format identifier W#16#0000 to W#16#7FFF.
Byte Data type Meaning
0 to 1 WORD Format identifier for the structure of the following data serving as additional
interrupt information
W#16#0000 to W#16#7FFF: manufacturer-specific diagnostics
2 to n BYTE See manufacturer's manual