Technical data

Table Of Contents
DPV1 SFBs According to PNO AK 1131
System Software for S7-300/400 System and Standard Functions - Volume 1/2
A5E00709327-01
8-17
Error Information
The output parameter STATUS contains information. It is interpreted as
ARRAY[1...4] OF BYTE the error information has the following structure:
Field element Name: Meaning
STATUS[1] Function_Num
B#16#00, if no error
Function ID from DPV1-PDU: In error case B#16#80
is OR linked. If no DPV1 protocol element is used:
B#16#C0.
STATUS[2] Error_Decode Location of the error ID
STATUS[3] Error_Code_1 Error ID
STATUS[4] Error_Code_2 Manufacturer specific error ID expansion
STATUS[2] can have the following values:
Error_Decode
(B#16#...)
Source Meaning
00 to 7F CPU No error or no warning
80 DPV1 Error according to IEC 61158-6
81 to 8F CPU B#16#8x shows an error in the nth call parameter of the
SFB.
FE, FF DP Profile Profile-specific error