Local Data for Time-Delay Interrupt OBs
The following table describes the temporary (TEMP) variables for a time-delay
interrupt OB. The variable names are the default names of OB20.
Variable Type Description
OB20_EV_CLASS BYTE Event class and identifiers:
B#16#11: interrupt is active
OB20_STRT_INF BYTE B#16#21: start request for OB20
(B#16#22: start request for OB21)
(B#16#23: start request for OB22)
(B#16#24: start request for OB23)
OB20_PRIORITY BYTE Assigned priority class: default values 3 (OB20) to 6
(OB23)
OB20_OB_NUMBR BYTE OB number (20 to 23)
OB20_RESERVED_1 BYTE Reserved
OB20_RESERVED_2 BYTE Reserved
OB20_SIGN WORD User ID: input parameter SIGN from the call for SFC32
(SRT_DINT)
OB20_DTIME TIME Configured delay time in ms
OB20_DATE_TIME DATE_AND_TIME DATE_AND_TIME of day when the OB was called