Technical data

Table Of Contents
Generating Block-Related Messages
System Software for S7-300/400 System and Standard Functions - Volume 2/2
A5E00739858-01
24-15
Error Information
The following table contains all the error information specific to SFB 35 that can be
output with the ERROR and STATUS parameters.
ERROR STATUS (Decimal) Explanation
0 11 Warning: Message lost, at least one signal transition/message could
not be sent.
0 22
Error in the pointer to the associated values SD_i:
- relating to the data length or the data type
- no access to associated values in user
memory, for example, due to deleted DB
or area length error
The activated message is sent without associated values
The actual parameter you have selected for SEVERITY is
higher than the permitted range. The activated message
will be sent with SEVERITY=127.
0 25 Communication was initiated. The message is being processed.
1 1 Communications problems: connection aborted or no logon
With acknowledgment-triggered reporting active: temporary display, if
no display devices support acknowledgment-triggered reporting
1 4 At the first call:
The specified EV_ID is outside the permitted range or
The ANY pointer SD_i has a formal error
The maximum memory area that can be sent for the CPU per
SFB 35 was exceeded
1 10 Access to local user memory not possible (for example, access to a
deleted DB)
1 12 When the SFB was called:
An instance DB that does not belong to SFB 35 was specified
A shared DB instead of an instance DB was specified
1 18 EV_ID was already being used by one of the SFBs 31 or 33 to 36.
1 20 Not enough working memory.
H-System: SFB called while update in progress
1 21 The message with the specified EV_ID is disabled.
Note
After the first block call. all the bits of the ACK_STATE output are set and it is
assumed that the previous values of inputs SIG_i, 1<
i < 8 were 0.