Technical data

Table Of Contents
SFBs for Compact CPUs
System Software for S7-300/400 System and Standard Functions - Volume 2/2
28-2
A5E00739858-01
Parameter Declarat
ion
Data
type
Address
(Instance
DB)
Range of
values
Default Description
LADDR
INPUT WORD 0 CPU specific W#16#0310 The I/O address of your
submodule, specified
by you in "HW Config".
If the E and A
addresses are not
equal, the lower one of
the two must be
specified.
CHANNEL
INPUT INT 2
0 0 Channel number
STOP
INPUT BOOL 4.4 TRUE/FALSE FALSE Stop run
With STOP = TRUE
you can stop/interrupt
the run prematurely.
ERR_A
INPUT BOOL 4.5 TRUE/FALSE FALSE Collect
acknowledgment for
external error
External errors are
cleared acknowledged
with ERR_A = TRUE.
SPEED
INPUT DINT 12 Creep speed
up to
1,000,000
pulses/s
No higher than
the maximum
speed
declared in the
parameter
1000 The axis is accelerated
to the speed "V
Setpoint
”.
It is not possible to
change the speed
during the run.
WORKING
OUTPUT BOOL 16.0 TRUE/FALSE FALSE Run is in progress
ACT_POS
OUTPUT DINT 18
-5x10
8
to
+5x10
8
pulses
0 Actual position value
MODE_OUT
OUTPUT INT 22 0, 1, 3, 4, 5 0 Active/configured
operating mode