Technical data

Table Of Contents
SFBs for Compact CPUs
System Software for S7-300/400 System and Standard Functions - Volume 2/2
28-4
A5E00739858-01
Parameters not assigned to the block (Statistical local data):
Parameter Declaration Data
type
Address
(Instance
DB)
Range of
values
Default Description
ACCEL
STATIC DINT 30 1 to 100,000
pulses/s
2
100 Acceleration
Change during run
not possible.
DECEL
STATIC DINT 34 1 to 100,000
pulses/s
2
100 Deceleration
Change during run
not possible.
CHGDIFF_P
STATIC DINT 38
0 to +10
8
pulses
1000 Changeover
difference plus:
"Changeover
difference plus"
defines the change-
over point from
which the drive
continues its forward
run with creep
speed.
CUTOFF-
DIFF_P
STATIC DINT 42
0 to +10
8
pulses
100 Cut-off difference
plus:
"Cut-off difference
plus" defines the
cut-off point at which
the drive forward run
at creep speed is
switched off.
CHGDIFF_M
STATIC DINT 46
0 to +10
8
pulses
1000 Changeover
difference minus:
"Changeover
difference minus"
defines the
changeover point
from which the drive
continues with a
reverse run at creep
speed.
CUTOFF-
DIFF_P
STATIC DINT 50
0 to +10
8
pulses
100 Cut-off difference
minus:
"Cut-off difference
plus" defines the
cut-off point at which
the drive reverse run
at creep speed is
switched off.
PARA
STATIC BOOL 54.0 TRUE/FALSE FALSE Parameters have
been assigned to
the axis