Explanation
W#16#2002 Wrong SFB, use SFB 44
W#16#2004 Wrong channel number (CHANNEL). Set channel "0"
W#16#3001 Run job rejected because of job error in the same SFB call. Correct the respective JOB
parameters
W#16#3002 A change of MODE_IN is not permitted while the drive is in operation. Wait for the end
of the current positioning run.
W#16#3003 Unknown operating mode (MODE_IN). Permitted is 1 (jog), 3 (reference run), 4
(Relative Step Approach) and 5 (absolute Step Approach).
W#16#3004 Only one start request is allowed the same time. Valid start requests are DIR_P, DIR_M
or START.
W#16#3005 START is only allowed in operating mode "Absolute Step Approach". Start the run with
DIR_P or DIR_M
W#16#3006 DIR_P or DIR_M is not allowed for linear axis and in operating mode "Absolute Step
Approach". Start the run with START
W#16#3007 Axis not synchronized. "Absolute Step Approach" is only possible synchronized axis.
W#16#3008 Clear working range. Return run to working position is only allowed in jog mode.
W#16#3101 No start enable because the axis is not parameterized. Parameterize the "Positioning"
submodule via HWConfig
W#16#3102 Start not enabled because the drive is not enabled. Set "Enable Drive" on the SFB
(DRV_EN=TRUE)
W#16#3103 Start not enabled because STOP is set. Clear the STOP on the SFB (STOP=FALSE)
W#16#3104 Start not enabled because the drive is currently performing a positioning run
(WORKING=TRUE). Wait for the end of the current positioning run.
W#16#3105 Start not enabled because at least one pending error has not been cleared. First,
eliminate and clear all external errors and the restart the run.
W#16#3202 Wrong speed setpoint in SPEED. The speed setpoint is out of the permitted range
of the creep speed of up to 1000000 pulses/s, though not higher than the
parameterized maximum speed.
W#16#3203
The acceleration setpoint in ACCEL is out of the range of 1 to 100,000 pulses/s
2
.
W#16#3204
The deceleration setpoint in DECEL is out of the range of 1 to 100,000 pulses/s
2
.
W#16#3206 The speed setpoint in SPEED must be higher than / equal to the parameterized
referencing frequency.
W#16#3301 Changeover/cut-off difference is too high. Set a maximum changeover/cut-off
difference of 10
8
W#16#3304 Cut-off difference too low. The cut-off difference must be at least half the size of the
target range.
W#16#3305 Changeover difference too low. The changeover difference must be at least half the
size of the target range.
W#16#3401 Target setting out of working range. For a linear axis and Step Approach the target
setting must be within the range of the software limit switches (inclusive).